The recommended resolution for system faults, inverter warnings, and inverter faults are provided below.
- Inverter Error Codes
Important: Only qualified people should perform the suggestions and recommended actions below. Always consult your installer.
Inverter Error Codes
Number |
Fault |
Tigo Fault |
Diagnosis / Solution |
IE 001 |
TZ Protect Fault |
Over Current Fault |
1. Wait for a while to check if you're back to normal. |
IE 002 |
Grid Lost Fault |
Grid Lost Fault |
1. Wait to see if power returns and the system reconnects. |
IE 003 |
Grid Volt Fault |
Grid Voltage Fault |
1. Wait to see if power returns and the system reconnects. |
IE 004 |
Grid Freq Fault |
Grid Frequency Fault |
1. Wait to see if power returns and the system reconnects. |
IE 005 |
PV Volt Fault |
PV Voltage Fault |
1. Check the output voltage of the PV modules. If string voltage is greater than 600VDC, shut down the system and troubleshoot the strings. |
IE 006 |
Bus Volt Fault |
Buss Voltage Fault |
1. Press the 'ESC' key to restart the inverter. |
IE 007 |
Bat Volt Fault |
Battery Voltage Fault |
1. Check battery input voltage is in normal range. |
IE 008 |
AC10M Volt Fault |
Grid Voltage Fault |
1. System returns to normal when the Grid returns to normal. |
IE 009 |
DCI OCP Fault |
DCI Overcurrent Protection Fault |
1. Wait for it to return to normal. |
IE 010 |
Reserved |
|
|
IE 011 |
SW OCP Fault |
Software Detection of Overcurrent Fault |
1. Wait for the system to return to normal. |
IE 012 |
RC OCP Fault |
Overcurrent Protection Fault |
1. Check the impedance of DC input and AC output. |
IE 013 |
Isolation Fault |
Insulation Fault |
1. Wait for the system to return to normal. |
IE 014 |
Temp Over Fault |
Temperature Fault |
1. Check if ambient temperature exceeds the equipment limits. If exceeded, move or shade equipment. See installation requirements. |
IE 015 |
Bat Con Dir Fault |
Battery Connection Fault |
1. Check for reversed Battery input lines. |
IE 016 |
Missed CT Fault |
- |
- |
IE 017 |
EPS(Off-grid) Overload Fault |
EPS(Off-Grid) Over Load Fault |
1. Shutdown the high-power device in the EPS panel and press the "ESC" key to restart the inverter. |
IE 018 |
OverLoad Fault |
On-Grid Mode Overload Fault |
1. Shutdown the high-power device and press the "ESC" key to restart the inverter. |
IE 019 |
PV Conn Dir Fault |
PV Direction Fault |
1. Check if the PV input lines are reversed. |
IE 020 |
BatPowerLow |
Battery Power Low Fault |
1. Shutdown the high-power device and press the "ESC" key to restart the inverter. |
IE 021 |
Low Temp |
Low Temperature fault |
1. Check if the ambient temperature is too low. |
IE 022 |
Reserved |
- |
- |
IE 023 |
Charger Relay Fault |
Charge Relay Fault |
1. Press the "ESC" key to restart the inverter. |
IE 024 |
BMS Lost |
Battery Communication Fault |
1. Check communication cables between Battery and Inverter are properly connected. |
IE 025 |
Inter Comms Fault |
Internal Communication Fault |
1. Shut down PV array, battery, and grid. |
IE 026 |
Fan Fault |
Fan Fault |
1. Check for foreign matter that could cause the fan to function improperly. |
IE 027 |
Earth Relay Fault |
EPS(Off-Grid) Earth Relay Fault |
1. Press the "ESC" key to restart the inverter. |
IE 028 |
|
|
|
IE 029 |
RCD Fault |
Residual Current Device Fault |
1. Check the impedance of DC input and AC output. |
IE 030 |
EPS(Off-grid) Relay Fault |
EPS(Off-Grid) Relay Failure |
1. Disconnect PV+/PV-, grid and batteries, then reconnect. |
IE 031 |
Grid Relay Fault |
Electrical Relay Failure |
1. Disconnect PV+/PV-, grid and batteries, then reconnect. |
IE 032 |
|
|
|