Tigo's Cloud Connect Advanced (CCA) is a powerful network hub and data-logger, the heart of our smart solutions.
The power supply for the Cloud Connect Advanced draws less than 1A, so these can be installed on minimally sized (10A or more) circuits. For feeding wires serving a 10A circuit and the DIN Rail Power Supply, use code compliant conductors de-rated for your conditions. (NEC 310.15 in the USA).
For the wires going from the DIN rail power supply to the CCA unit inside the provided enclosure, use AWG #20 or larger wires.
Cloud Connect Advanced Outdoor Kit, DIN Rail Power Supply Includes:
Interior of outdoor enclosure showing Cloud Connect Advanced and DIN Rail Power Supply. For further information, see the CCA & TAP Installation Quick Start Guide in our Guides and Manuals download area. P/N: 348-00000-52 |
DIN rail power supply:
- Not outdoor rated, install in enclosure
- Input: 100-240VAC - 50/60Hz 0.88A
- Output: 24VDC @ 1A
If you would rather purchase the devices without a power supply or enclosure, you can buy them as standalone products.
CCA Standalone - P/N 346-00000-00
TAP - P/N 158-00000-02