Aleksandra Radchenko
Tigo Employee
Community Moderator
- 合計アクティビティ 28
- 前回のアクティビティ
- メンバー登録日
- フォロー 0ユーザー
- フォロワー 0ユーザー
- 投票 2
- サブスクリプション 16
アクティビティの概要
Aleksandra Radchenkoさんの最近のアクティビティ-
Aleksandra Radchenkoさんがコメントを作成しました:
正式なコメント Thank you for reaching out for some design insight. Yes, you can use optimization to prevent power loss across strings mounted at different orientations. You should still assure that your south and...
-
Aleksandra Radchenkoさんがコメントを作成しました:
Hello Luis, Thank you for reaching out for clarification. Considering your string lengths, each string should have a maximum voltage output of (modules in string * Voc) 389 volts. The TS4-A-2F and ...
-
Aleksandra Radchenkoさんがコメントを作成しました:
Hello Stephen, Please note that a this time, the Sol-Ark-12k-P has only been UL certified with our RSS Transmitter, our TS4-A-F, and our TS4-A-2F, products. You can confirm this by visiting our UL ...
-
Aleksandra Radchenkoさんがコメントを作成しました:
正式なコメント Hello John,The Tigo Portal (or App) gives you the ability to input brand new Manufacturers and Models, into the list of Equipment options. To do this, scroll to the bottom of the Equipment list(s) ...
-
Aleksandra Radchenkoさんがコメントを作成しました:
正式なコメント Hello Steve, I am going to guess that you are looking at our energy view and not our power view, which indeed is the cumulative power produced over a day. The power view shows the real-time product...
-
Aleksandra Radchenkoさんがコメントを作成しました:
Hello tigo.nabcep, The input specifications vary slightly depending on the TS4-A-F and TS4-A-O models in question, and it is worth noting the TS4-A-F's Operating Temperature Range is -40°C to +85°C...
-
Aleksandra Radchenkoさんがコメントを作成しました:
ovsims No worries! I was making sure you were not using our TS4-A-F or TS4-A-2F, for which we do not provide monitoring. At this time I would like to notify you that the SMA SB 5.0-1SP-US-41 invert...
-
Aleksandra Radchenkoさんがコメントを作成しました:
正式なコメント Hi there O, Thank you for that question. To answer, I need to know what model of inverter you are using, and what TS4 models you have installed: I ask about the TS4 model because our TS4-A-O, TS4-...
-
Aleksandra Radchenkoさんがコメントを作成しました:
Hi Ben,Both optimizers and microinverters are means of achieving maximum power point tracking on the module level, and they can both be used to mitigate production loss (for example: due to shading...
-
Aleksandra Radchenkoさんが記事を作成しました:
通信なしにTS4をインストール
TS4-Oのオプティマイジング機能には、PIV (Predictive IV)があります。 PIVによって、TS4ユニットは通信なしで独立してフル最適化ができます。 詳しくはこの資料をご覧ください。 そのため、周辺機器の構成なしで、TS4-R-Oの取付けや、スマートモジュールの最適化ができ、装置自体で発電量をを最大化します。 ただインタラクティブインストールおよび安全マニュアルおよびインスト...