This article introduces our TS4-A family of FLEX MLPE products. They include module level devices that offer wireless communication, or powerline communication (PLC) solutions.
For Design Specific Application: Module-level Disconnect for Safest Solar
TS4-A is an add-on (or retrofit) product that can be used with any compatible PV-Module. Refer to the module manufacturer's datasheet for voltage and current parameters.
Note: The functionality of the TS4-A series is incremental. For example: TS4-A-M (Monitoring) includes functionalities that are also available on the TS4-A-S (Safety), and TS4-A-O (Optimizer) models.
Optimization
TS4-A-O
- Provides Module and String Optimization
- Compliant with NEC 690.12 Rapid Shutdown requirements
- Assists or amends uneven parallel strings and orientation issues
- Design into shade for maximized roof usage and design flexibility
Safety
TS4-A-S
- Same string design rules as traditional modules
- Compliant with NEC 690.12 Rapid Shutdown requirements
- Requires CCA & TAP for communication
- Systems requiring rapid shutdown (RSD), should have TS4-S or higher on ALL modules.
Monitoring
TS4-A-M
- Same string design rules as previous Tigo MLPEs
- Can be deployed on any system size
- Requires CCA and TAP for communication
- Does not offer RSD (rapid shutdown) solution
Fire Safety (PLC)
TS4-A-F
- Solution for NEC 690.12 Rapid Shutdown requirements
- Requires PLC (powerline communication) RSS Signal Transmitter
Dual-Module Fire Safety (PLC)
TS4-A-2F
- Dual-Module connection
- Inexpensive solution for NEC 690.12 Rapid Shutdown requirements
- Requires PLC (powerline communication) RSS Signal Transmitter